ENGINE CONTROLS 1F–289
DAEWOO M-150 BL2
Lack of Power, Sluggishness, or Sponginess (Cont’d)
Step Action Value(s) Yes No
15
Repair or replace any engine components as
needed.
Is the repair complete?
–
System OK
–
16
1. Check the Engine Control Module (ECM) grounds
for being clean, tight, and in their proper location.
2. Check the exhaust recirculation valve for being
open or partially open all the time.
3. Check the torque converter clutch operation.
4. Check the A/C system operation.
5. Check the generator output.
6. Repair the generator if the output is not within the
specified range.
Are all checks and repairs complete?
12–16 V System OK
–