Chapter 11
| Interface Commands
Transceiver Threshold Configuration
– 431
Transceiver Threshold Configuration
transceiver-monitor This command sends a trap when any of the transceivers operational values fall
outside of specified thresholds. Use the no form to disable trap messages.
Syntax
transceiver-monitor
Default Setting
Disabled
Command Mode
Interface Configuration (SFP/SFP+ Ports)
Example
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-monitor
Console#
transceiver-threshold-
auto
This command uses default threshold settings obtained from the transceiver to
determine when an alarm or warning message should be sent. Use the no form to
disable this feature.
Syntax
transceiver-threshold-auto
Default Setting
Enabled
Command Mode
Interface Configuration (SFP/SFP+ Ports)
Example
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold-auto
Console#