Proline Promag 300 Modbus RS485 Modbus RS485 Register Information
Endress+Hauser 249
"PFS output 1 to n" submenu
Navigation: Expert → Output → PFS output 1 to n
Parameter Register Data type Access Selection / User entry / User interface → 
Terminal no. (0492–1 to n) 1: 6551
2: 6552
3: 6553
Integer Read 0 = Not used
2 = 24-25 (I/O 2)
3 = 22-23 (I/O 3)
119
Signal mode (0490–1 to n) 1: 6235
2: 6236
3: 6237
Integer Read / Write 0 = Passive
2 = Active
120
Operating mode (0469–1 to n) 1: 4479
2: 4480
3: 9907
Integer Read / Write 0 = Pulse
1 = Switch
53 = Frequency
120
Assign pulse 1 to n (0460–1 to n) 1: 2461
2: 2462
3: 4685
Integer Read / Write 0 = Off
1 = Volume flow
2 = Mass flow
3 = Correct.vol.flow
122
Value per pulse (0455–1 to n) 1: 3034 to 3035
2: 3036 to 3037
3: 4714 to 4715
Float Read / Write Signed floating-point number 122
Pulse width (0452–1 to n) 1: 2836 to 2837
2: 2838 to 2839
3: 4702 to 4703
Float Read / Write 0.05 to 2 000 ms 123
Measuring mode (0457–1 to n) 1: 2394
2: 2395
3: 4683
Integer Read / Write 0 = Forward flow
1 = Reverse flow
2 = Rev. flow comp.
13 = Forward/Reverse
123
Failure mode (0480–1 to n) 1: 2948
2: 2949
3: 4708
Integer Read / Write 0 = Actual value
1 = No pulses
124
Pulse output 1 to n (0456–1 to n) 1: 3082 to 3083
2: 3084 to 3085
3: 4718 to 4719
Float Read Positive floating-point number 125
Assign freq. (0478–1 to n) 1: 2614
2: 2615
3: 9915
Integer Read / Write 0 = Off
1 = Volume flow
2 = Mass flow
3 = Correct.vol.flow
4 = Conductivity
*
7 = Temperature
*
9 = CorrConductivity
*
37 = Flow velocity
39 = Electronic temp.
126
Min. freq. value (0453–1 to n) 1: 3526 to 3527
2: 3528 to 3529
3: 5767 to 5768
Float Read / Write 0.0 to 10 000.0 Hz 126
Max. freq. value (0454–1 to n) 1: 2996 to 2997
2: 2998 to 2999
3: 4710 to 4711
Float Read / Write 0.0 to 10 000.0 Hz 127
Val. at min.freq (0476–1 to n) 1: 5887 to 5888
2: 5889 to 5890
3: 5891 to 5892
Float Read / Write Signed floating-point number 127
Val. at max.freq (0475–1 to n) 1: 3514 to 3515
2: 3516 to 3517
3: 5759 to 5760
Float Read / Write Signed floating-point number 128
Measuring mode (0479–1 to n) 1: 2922
2: 2923
3: 4706
Integer Read / Write 0 = Forward flow
2 = Rev. flow comp.
13 = Forward/Reverse
128