Command Line Interface
588 1553-KDU 137 365 Uen D 2006-06-16
7.5.35 logging facility
This command sets the facility type for remote logging of syslog messages. Use
the no form to return the type to the default.
Syntax
[no] logging facility <type>
type - A number that indicates the facility used by the syslog server to
dispatch log messages to an appropriate service. (Range: 16-23)
Default Setting
23
Command Mode
Global Configuration
Command Usage
The command specifies the facility type tag sent in syslog messages. (See
RFC 3164.) This type has no effect on the kind of messages reported by the
ECN330-switch. However, it may be used by the syslog server to sort
messages or to store messages in the corresponding database.
Example
Console(config)#logging facility 19
Console(config)#