Command Line Interface
7811553-KDU 137 365 Uen D 2006-06-16
In the default auto mode, power is automatically supplied when a
device is detected on the port, providing that the power demanded does
not exceed ECN330’s power budget.
Example
7.13.3 power inline maximum allocation
This command limits the power allocated to specific ports. Use the no form to
restore the default setting.
Syntax
power inline maximum allocation <milliwatts>
no power inline maximum allocation
miliwatts - The maximum power budget for the port.
(Range: 3000 - 24700 milliwatts).
Note: The maximum power allocation that configured is 24700 milliwatts.
However, the maximum guaranteed power that can be delivered to any port is
only 23100 miliwatts.
Default Setting
24700 milliwatts
Command Mode
Interface Configuration
Console(config)#interface ethernet 1/1
Console(config-if)#power inline auto
Console(config-if)#exit
Console(config)#interface ethernet 1/2
Console(config-if)#no power inline
Console(config-if)#