Command Line Interface
830 1553-KDU 137 365 Uen D 2006-06-16
On transit nodes, the default value for the fail time can be used until
receiving a control message from the master node to update their
timers.
Example
Related Commands
hellotime (section 7.16.3 on page 828)
7.16.5 port
This command sets the port type attached to the ring as primary or secondary.
Each node must connect to the ring through two ports as part of the protection
switching scheme – one port as the primary port and another as the secondary
port. Use the no form to remove a primary or secondary port from the ring.
Syntax
port {primary | secondary} <port-number>
no port {primary | secondary}
primary - This port is open on the Protected VLAN and is used
for passing both control messages and data traffic. The master
node sends control messages from this port.
secondary - This port is blocked on the Protected VLAN and is
used only to receive control messages on the master node.
port-number - Range: 1-27
Default Setting
None
Console(config-eaps)#failtime 3
Console(config-eaps)#