Table 79: FRU Power Requirements (continued)
Maximum Power RequirementPart NumberComponent
590 WMS-MPC-128GMultiservices
MPC
610 W
With optics:
607 W at 55° C, with SFPP ZR optics
584 W at 40° C, with SFPP ZR optics
565 W at 25° C, with SFPP ZR optics
MPC4E-3D-32XGE-SFPP32x10GE
MPC4E
610 W
With optics:
607 W at 55° C, with SFPP ZR and CFP LR4 optics
584 W at 40° C, with SFPP ZR and CFP LR4 optics
565 W at 25° C, with SFPP ZR and CFP LR4 optics
MPC4E-3D-2CGE-8XGE2x100GE +
8x10GE
MPC4E
With optics:
607 W at 55° C
541 W at 40° C
511 W at 25° C
MPC5E-40G10G
MPC5EQ-40G10G
6x40GE +
24x10GE
MPC5E
6x40GE +
24x10GE
MPC5EQ
With optics:
607 W at 55° C
541 W at 40° C
511 W at 25° C
MPC5E-100G10G
MPC5EQ-100G10G
2x100GE +
4x10GE
MPC5E
2x100GE +
4x10GE
MPC5EQ
With optics:
545 W at 55° C
465 W at 40° C
440 W at 25° C
MPC7E-MRATEMPC7E
(Multi-Rate)
MPCs
165 W
With MICs and optics:
239 W at 55° C
227 W at 40° C
219 W at 25° C
MX-MPC1-3D
MX-MPC1E-3D
MPC1
MPC1E
Copyright © 2017, Juniper Networks, Inc.142
MX480 3D Universal Edge Router Hardware Guide