Table 79: FRU Power Requirements (continued)
Maximum Power RequirementPart NumberComponent
175 W
With MICs and optics:
249 W at 55° C
237 W at 40° C
228 W at 25° C
MX-MPC1-3D-Q
MX-MPC1E-3D-Q
MPC1 Q
MPC1E Q
274 W
With MICs and optics:
348 W at 55° C
329 W at 40° C
315 W at 25° C
MX-MPC2-3D
MX-MPC2E-3D
MPC2
MPC2E
294 W
With MICs and optics:
368 W at 55° C
347 W at 40° C
333 W at 25° C
MX-MPC2-3D-Q
MX-MPC2E-3D-Q
MX-MPC2-3D-EQ
MX-MPC2E-3D-EQ
MPC2 Q
MPC2E Q
MPC2 EQ
MPC2E EQ
294 W
With MICs and optics:
368 W at 55° C
347 W at 40° C
333 W at 25° C
MX-MPC2E-3D-PMPC2E P
474 W
With MICs and optics:
474 W at 55° C
417 W at 40° C
400 W at 25° C
MPC2E-3D-NGMPC2E NG
529 W
With MICs and optics:
529 W at 55° C
460 W at 40° C
438 W at 25° C
MPC2E-3D-NG-QMPC2E NG Q
143Copyright © 2017, Juniper Networks, Inc.