1002 Matrix ETERNITY NE System Manual
Power Fail Transfer
When the power supply to SARVAM UCS fails, SLT 1 is automatically connected to the CO1. The PBX switches
from normal functioning mode to the Power Failure Connection mode. Only CO1 trunk can be used during a power
failure. Outgoing calls can be made from SLT1 extension as well as incoming calls on the CO1 trunk can land on
this extension. When power is resumed and normal functioning of the system is restored, calls on the Power Failure
Connection remains unaffected until they are terminated.
Feature Interactions
Forced Call Disconnection: If the extension user is in conversation over PFT port, when the power supply to
SARVAM UCS fails and the power supply is restored during the ongoing conversation, then other extension users
cannot invoke Forced Call Disconnection on the PFT SLT or CO port.
If an extension, that has Forced Call Disconnection enabled in its CoS and a higher priority than the called
extension, invokes Forced Call Disconnection on PFT port, then the system will provide error tone and display the
message Forced Call Rel Not Alwd on the phone LCD.
ACB (Auto Call back): If the extension user is in conversation over PFT port, when the power supply to SARVAM
UCS fails and the power supply is restored during the ongoing conversation, then the system will allow other
extension users to set ACB on the PFT SLT or CO port.
RAID: If the extension user is in conversation over PFT port, when the power supply to SARVAM UCS fails and the
power supply is restored during the ongoing conversation, then the system will not allow other extension users to
invoke RAID on the called PFT SLT or CO port.
If the calling extension has RAID enabled in the CoS and has a higher priority than the called PFT extension/trunk
and it invokes RAID, then the system will give error tone and display message Raid Not Allowed on the phone LCD.
Barge - In: If the extension user is in conversation over PFT port, when the power supply to SARVAM UCS fails
and the power supply is restored during the ongoing conversation, then the system will not serve Barge-In request
on the busy PFT SLT.
Interrupt request: If the extension user is in conversation over PFT port, when the power supply to SARVAM UCS
fails and the power supply is restored during the ongoing conversation, then the system will not serve Interrupt
Request on the busy PFT SLT.
Trunk reservation: If the extension user is in conversation over PFT port, when the power supply to SARVAM
UCS fails and the power supply is restored during the ongoing conversation, then the system will allow other
extension users to set Trunk reservation on the busy PFT CO port.

Table of Contents