86 Matrix ETERNITY NE System Manual
Starting Up ETERNITY NENX
Power ON
• Connect the power adapter to ETERNITY NENX.
• Plug in the power adapter of ETERNITY NENX into the power outlet.
• Switch on the power supply and wait for the Reset Cycle to complete.
ETERNITY NENX supports a Power Fail Transfer Module, which enables you to receive and make calls
even during power fail conditions. For more details, see “Power Fail Transfer”.
LED Indication
• At Power ON, Power LED will turn ON (Continuous Green).
• System LED (STS) will display following error/events/status.
• Mobile Ports take about 3 minutes to get registered with the network.
You may now access the web-based programming tool, Jeeves that is, the SARVAM UCS SOHO Application and
configure the same.
LED Status Colour Comment
1sec On - 1sec Off (Continuous) Green ETERNITY NENX started successfully.
5sec On - 5sec Off (Continuous) Green
Software Mismatch (uboot checksum did
not match)
10sec On - 10sec Off (Continuous) Green Flash Lock due to License
100msec ON - 100msec OFF - 100msec ON -
100msec OFF - 100msec ON - 5000msec
OFF
Green
Recovery Mode
a
a. If you get Recovery Mode LED status, contact Matrix Support Team.