5.3 UL Standards
172 SIEPCYEUOQ2V01A Q2V Technical Manual
Model Terminal
Recommended
Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Wire
Stripping
Length
*1
mm
Terminal Screw
Tightening Torque
Nm (inlb)
Size Shape
B012
L/L1, N/L2 8 14 - 8 10 M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 12 14 - 10 10 M4
1.5 - 1.7
(13.5 - 15)
-, +1 8 14 - 8 10 M4
1.5 - 1.7
(13.5 - 15)
B1, B2 14 14 - 12 10 M4
1.5 - 1.7
(13.5 - 15)
10
*2
14 - 10
*2
- M4
1.2 - 1.5
(10.6 - 13.3)
B018
L/L1, N/L2 8 12 - 6 10 M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 10 14 - 8 10 M4
1.5 - 1.7
(13.5 - 15)
-, +1 8 12 - 6 10 M4
1.5 - 1.7
(13.5 - 15)
B1, B2 14 14 - 12 10 M4
1.5 - 1.7
(13.5 - 15)
8
*2
12 - 8
*2
- M5
2.0 - 2.5
(17.7 - 22.1)
*1 Remove insulation from the ends of wires to expose the length of wire shown.
*2 If you turn on the internal EMC filter, the leakage current of the drive will be more than 3.5 mA. Use these closed-loop crimp
terminals or equivalent to connect a protective ground wire that has a minimum cross-sectional area of 10 mm
2
(copper wire).
8-4NS from JST Mfg. Co., Ltd.
R8-4S from NICHIFU Co., Ltd.
Three-Phase 400 V Class (UL Compliance)
Model Terminal
Recommended
Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Wire
Stripping
Length
*1
mm
Terminal Screw
Tightening Torque
Nm (inlb)
Size Shape
4001
R/L1, S/L2, T/L3 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
U/T1, V/T2, W/T3 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
-, +1, +2 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
B1, B2 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
14
*2
14 - 10
*2
- M4
1.2 - 1.5
(10.6 - 13.3)
4002
R/L1, S/L2, T/L3 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
U/T1, V/T2, W/T3 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
-, +1, +2 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
B1, B2 14 14 - 12 8 M3
0.5 - 0.6
(4.4 - 5.3)
14
*2
14 - 10
*2
- M4
1.2 - 1.5
(10.6 - 13.3)