EasyManuals Logo

Omron Q2V Series User Manual

Omron Q2V Series
734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #426 background imageLoading...
Page #426 background image
11.21 Parameters Changed by PM Motor Code Selection
426 SIEPCYEUOQ2V01A Q2V Technical Manual
No. Name Unit Motor Code (setting value of E5-01)
E5-03 PM Mot Rated Current (FLA) A 27.71 39.6 55.5 65.6 75.1
E5-04 PM Mot Pole Count - 6 6 6 6 6
E5-05
PM Mot Resistance (Ohms/
Phase)
Ω 0.184 0.099 0.075 0.057 0.041
E5-06
PM d-Axis Inductance (mH/
Phase)
mH 6.91 4.07 3.29 2.53 1.98
E5-07
PM q-Axis Inductance (mH/
Phase)
mH 7.66 4.65 3.84 3.01 2.60
E5-09
PM BackEMF Vpeak (mV/(rad/
s))
mVs/rad 335.0 303.9 311.2 300.9 327.7
E5-24
PM BackEMF L-L Vrms (mV/
rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0
E1-04 Max Output Frequency Hz 72.5 72.5 72.5 72.5 72.5
E1-05 Max Output Voltage V 190.0 190.0 190.0 190.0 190.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5
E1-09 Min Output Frequency Hz 3.6 3.6 3.6 3.6 3.6
L3-24
*1
Acc@Rated Torque s 0.084 0.096 0.085 0.080 0.122
n5-02 Mot Inertia Acceleration Time s 0.084 0.096 0.085 0.080 0.122
n8-49 Heavy Load Id Current % -6.0 -9.3 -10.7 -13.2 -15.7
*1 The default setting changes when the setting for o2-04 [Drive KVA Selection] changes.
Table 11.15 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Mot Code Selection - 1332 1333 1335 1336 1338 133A
Voltage Class V 400 400 400 400 400 400
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5
Motor Rotation Speed min
-1
1450 1450 1450 1450 1450 1450
E5-02 PM Mot Rated Power (kW) kW 0.4 0.75 1.5 2.2 3.7 5.5
E5-03 PM Mot Rated Current (FLA) A 0.94 1.56 2.81 4.27 6.98 10.21
E5-04 PM Mot Pole Count - 6 6 6 6 6 6
E5-05
PM Mot Resistance (Ohms/
Phase)
Ω 12.760 7.421 4.825 2.656 1.353 0.999
E5-06
PM d-Axis Inductance (mH/
Phase)
mH 128.60 85.11 58.87 46.42 31.73 26.20
E5-07
PM q-Axis Inductance (mH/
Phase)
mH 166.96 113.19 80.59 60.32 40.45 30.94
E5-09
PM BackEMF Vpeak (mV/
(rad/ s))
mVs/rad 528.6 544.2 568.5 572.8 562.9 587.6
E5-24
PM BackEMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Max Output Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5
E1-05 Max Output Voltage V 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5
E1-09 Min Output Frequency Hz 3.6 3.6 3.6 3.6 3.6 3.6
L3-24
*1
Acc@Rated Torque s 0.098 0.071 0.066 0.087 0.085 0.072
n5-02
Mot Inertia Acceleration
Time
s 0.098 0.071 0.066 0.087 0.085 0.072
n8-49 Heavy Load Id Current % -6.6 -9.2 -13.5 -12.1 -13.7 -10.1
*1 The default setting changes when the setting for o2-04 [Drive KVA Selection] changes.