Remote control commands
R&S
®
SMA100B
627User Manual 1178.3834.02 ─ 09
The orientation of the angle can be set with [:SOURce<hw>]:VOR[:BANGle]:
DIRection.
Parameters:
<BAngle> float
Range: 0 to 360
Increment: 0.01
*RST: 0
Example: See Example "Configure and generate a VOR signal"
on page 596.
Manual operation: See "Bearing Angle" on page 139
[:SOURce<hw>]:VOR[:BANGle]:DIRection
<Direction>
Sets the reference position of the phase information.
Parameters:
<Direction> FROM | TO
FROM
The bearing angle is measured between the geographic north
and the connection line from beacon to airplane.
TO
The bearing angle is measured between the geographic north
and the connection line from airplane to beacon.
*RST: FROM
Example: See Example "Configure and generate a VOR signal"
on page 596.
Manual operation: See "Direction" on page 139
[:SOURce<hw>]:VOR:COMid:CODE <Code>
Sets the coding of the COM/ID signal by the international short name of the airport
(e.g. MUC for the Munich airport).
The COM/ID tone is sent according to the selected code, see Chapter D, "Morse code
settings", on page 784.
If no coding is set, the COM/ID tone is sent uncoded (key down).
Parameters:
<Code> string
Example: See Example "Configure and generate a VOR signal"
on page 596.
Manual operation: See "Code" on page 140
SOURce subsystem