Remote control commands
R&S
®
SMA100B
628User Manual 1178.3834.02 ─ 09
[:SOURce<hw>]:VOR:COMid:DASH <Dash>
Sets the length of a Morse code dash.
Parameters:
<Dash> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.3
Example: See Example "Configure and generate a VOR signal"
on page 596.
Manual operation: See "Dash Length" on page 141
[:SOURce<hw>]:VOR:COMid:DEPTh
<Depth>
Sets the AM modulation depth of the COM/ID signal.
Parameters:
<Depth> float
Range: 0 to 100
Increment: 0.1
*RST: 10
Example: See Example "Configure and generate a VOR signal"
on page 596.
Manual operation: See "Depth" on page 141
[:SOURce<hw>]:VOR:COMid:DOT <Dot>
Sets the length of a Morse code dot.
If the time schema is set to standard, the dash length (= 3 times dot length), symbol
space (= dot length) and letter space (= 3 times dot length) is also determined by this
entry.
Parameters:
<Dot> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.1
Example: See Example "Configure and generate a VOR signal"
on page 596.
Manual operation: See "Dot Length" on page 141
[:SOURce<hw>]:VOR:COMid:FREQuency <Frequency>
Sets the frequency of the COM/ID signal.
SOURce subsystem