Remote control commands
R&S
®
SMA100B
730User Manual 1178.3834.02 ─ 09
Parameters:
<Language> string
Example:
SYSTem:LANGuage "SCPI"
// selects SCPI command set
Manual operation: See "Language" on page 404
:SYSTem:INFormation:SCPI <InfoString>
Inserts system information in recorded SCPI command lists, for example information
on a missing command.
Parameters:
<InfoString> string
Example:
SYST:INF:SCPI "missing command"
enters the information into a recorded SCPI command list.
:SYSTem:SECurity:SANitize[:STATe]
<SecPassWord>, <MmemProtState>
Sanitizes the internal memory.
Parameters:
<MmemProtState> 0 | 1 | OFF | ON
*RST: 0
Setting parameters:
<SecPassWord> string
Example:
SYSTem:SECurity:SANitize[:STATe] 1
Manual operation: See "Sanitize" on page 365
:SYSTem:SECurity:SUPolicy <SecPassWord>, <UpdatePolicy>
Configures the automatic signature verification for firmware installation.
Parameters:
<UpdatePolicy> STRict | CONFirm | IGNore
*RST: n.a. (factory preset: CONFirm)
Setting parameters:
<SecPassWord> string
Manual operation: See "Secure Update Policy" on page 364
:SYSTem:SPECification? <Id>
Retrieves data sheet information for a specific parameter.