R&S FSL CALCulate Subsystem (CATV, K20)
1300.2519.12 6.423 E-11
CALCulate:ATV:LIMit:RESult Subsystem (CATV, K20)
The CALCulate:ATV:LIMit:RESult subsystem checks the measurement limits for analog TV
measurements.
Commands of the CALCulate:ATV:LIMit:RESult Subsystem
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S1IFoffset:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S1IFoffset:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S1PRelative:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S1PRelative:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S2IFoffset:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S2IFoffset:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S2PRelative:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S2PRelative:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:VCFoffset:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:VCFoffset:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:VCPabsolute:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:VCPabsolute:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CN:CN[:LOWer]?
CALCulate<1|2>:ATV:LIMit:RESult:CSO:CSO[:LOWer]?
CALCulate<1|2>:ATV:LIMit:RESult:CTB:CTB[:LOWer]?
CALCulate<1|2>:ATV:LIMit:RESult:HUM:HUM:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:HUM:HUM:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:VMODulation:MDEPth:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:VMODulation:MDEPth:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:VMODulation:RPC:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:VMODulation:RPC:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:VMODulation:VCPower:LOWer?
CALCulate<1|2>:ATV:LIMit:RESult:VMODulation:VCPower:UPPer?
CALCulate<1|2>:ATV:LIMit:RESult:CARRiers:S1IFoffset:LOWer?
This command performs a lower limit check for the frequency offset of the sound carrier 1.
The numeric suffixes <1|2> are irrelevant.
This command is a query and therefore has no *RST value.
Example
CALC:ATV:LIM:CARR:S1IF:LOW 1KHZ
Sets the lower frequency offset limit for sound carrier 1 to 1 kHz.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:ATV:LIM:RES:CARR:S1IF:LOW?
Performs a lower limit check for the frequency offset of the sound carrier 1.