Networking
Programming guide
A31003-K16-X001-3-7620
,
07/99
10-12
Hicom 100 E Version 2.1, Service manual
10.3.6 Route type
Each of the 4 possible routes can be defined either as "trunk" line types (default) or as "PBX"
line types.
In the case of the "trunk" line type, Hicom 100E checks for the (continuous) dial tone before
transmitting the dialling signal. A flash pulse is transmitted for 300 ms.
In the case of the "PBX" line type, the system does not check for a dial tone. Toll restriction is
only implemented if the trunk code of the main PBX is entered for the route in question. A flash
pulse is transmitted for 80 ms.
Example
: change the line type of route 2 from "trunk" to "PBX"
Input sequence Meaning Display
A 1 6 4 (up to
SW2.0.2)
1 6 14(as of SW2.1)
Line type of route 1
(select route 1–4 with "+" and "–" or
directly with "#")
Route 1: trunk
B+
Scroll to route 2 Route 2: trunk
C*
Change input Route 2:
D1
Line type route 2 = PBX Route 2: PBX
E<OK>
Confirm input Route 2: PBX
F
<F8> Return to Start menu System administration
The "trunk" line type can be programmed by entering "0" under point D.