Station attribute
s
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
10-55
Programming guide
10.6.9.2 Defining intercept, busy
If a DDI extension called via ISDN is busy, the
camp-on
feature is activated by default at this
extension. If the camped-on ISDN call is not picked up, the "Intercept, no answer" criterion
applies, see Section 10.6.9.1.
Provided the "camp-on rejection" feature (data security) has been enabled for the dialled busy
DDI extension, see Section 10.5.1.3, and the call destination list does not contain a forwarding
extension, the external ISDN caller receives the "busy" tone by default.
For this purpose, an
intercept to console, busy
feature can be defined. Such a modification
applies to the entire system.
Example
: programming intercept to console, busy.
10.6.9.3 Defining intercept, unavailable DDI number
If an external ISDN caller dials an unavailable or invalid DDI number, this call is automatically
forwarded to the intercept console immediately. This intercept feature can be deactivated by
appropriate programming so that the external ISDN caller hears the "busy" tone. This definition
applies to the entire system.
Example
: programming intercept override, unavailable DDI number.
Input sequence Meaning Display
A 1 5 1 5 2
Intercept, busy Intercept: no
B*
Change input Intercept:
C1
Select intercept Intercept: yes
D<OK>
Confirm input Intercept: yes
E
<F8> Return to Start menu System administration
Intercept, busy can be deactivated by entering "0" under point C.
Input sequence Meaning Display
A 1 5 1 5 3
Intercept, unavailable DDI no. Intercept: yes
B*
Change input Intercept:
C0
Select intercept override Intercept: no
D<OK>
Confirm input Intercept: no
E
<F8> Return to Start menu System administration
Intercept, unavailable DDI number can be reactivated by entering "1" under point C.