Station attributes
Programming guide
A31003-K16-X001-3-7620
,
07/99
10-54
Hicom 100 E Version 2.1, Service manual
10.6.8.3 Defining the console code
External ISDN calls are directly signalled at the intercept console if the console code is dialled
instead of the DDI number. The console code (by default "0") applies to the entire system and
can be changed.
Example
: the console code is to be changed to "9".
10.6.9 Defining intercept criteria
10.6.9.1 Defining intercept, no answer
An ISDN call from a directly dialled extension which was not answered is automatically
forwarded to the intercept console after a set period of time. The amount of time that elapses
before the call is forwarded (intercepted) corresponds to the number of ring attempts entered
in the call destination list for this extension Section 10.6.7.2.
The intercept feature can be deactivated by appropriate programming. The modification applies
to the entire system.
Example
: programming intercept override, no answer.
Input sequence Meaning Display
A 1 5 1 2
Console code with DDI Ext. no.: 0
B*
Change input Ext. no.:
C9
Select console code Ext. no.: 9
D<OK>
Confirm input Ext. no.: 9
E
<F8> Return to Start menu System administration
The console code can be deleted by pressing the F3 key under point C.
Input sequence Meaning Display
A 1 5 1 5 1
Intercept, no answer Intercept: yes
B*
Change input Intercept:
C0
Select intercept override Intercept: no
D<OK>
Confirm input Intercept: no
E
<F8> Return to Start menu System administration
Intercept, no answer can be reactivated by entering "1" under point C.