Station attribute
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
10-53
Programming guide
As of SW version 2.0.1+, the following also applies:
The intercept console at night can be cancelled by pressing the F3 key under point C. In this
way, it is possible to assign an individual night-time intercept console to each line (e.g. in the
case of different basic accesses).
Example
: ext. 12 is the night intercept console for the 1st basic access (line 1 and 2).
Call group 882 is the night intercept console for the 2nd basic access (line 3 and 4).
1. The actual "night intercept console" under code <1514> is deleted, see above.
2. The required intercept console extensions are assigned to lines 1 to 4.
Lines in a shared basic access must always be assigned the same intercept console
extension!
Input sequence Meaning Display
A 1 5 1 8
Intercept console per line at night
(select line 1–32 with "+" and "–" or
directly with "#")
Line 1: 11
B*
Change input Line 1:
C12
Select intercept console Line 1: 12
D<OK>
Confirm input Line 1: 12
E+
Scroll to line 2 Line 2: 11
F
* Change input Line 2:
G
12 Select intercept console Line 2: 12
H
<OK> Confirm input Line 2: 12
J
+ Scroll to line 3 Line 3: 11
K
* Change input Line 3:
L
882 Select intercept console Line 3: 882
M
<OK> Confirm input Line 3: 882
N
+ Scroll to line 4 Line 4: 11
O
* Change input Line 4:
P
882 Select intercept console Line 4: 882
R
<OK> Confirm input Line 4: 882
S
<F8> Return to Start menu System administration