Safety informatio
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
1-5
Important Information
1.1.4 General information
●
If the installation is brought into the operating premises from a cold environment,
condensation may occur. Wait until the temperature of the installation has adjusted to the
ambient temperature and until the installation is absolutely dry before you start it up.
●
Before starting wall assembly, check whether the load-bearing capacity of the wall is
adequate, e.g. in the event of plasterboard walls.
●
When maintenance work has been completed, always re-install all safety equipment in the
right place.
●
Check your tools regularly. Only use intact tools.
●
Close the doors after test and maintenance work has been completed.
●
All cables and lines which leave a system cabinet must be screened at least between the
connection point in the cabinet and the point at which the cable leaves the cabinet. Use a
clip and pressure screw to contact all screen fabric to the cabinet outlet. This is also
applicable for permanently connected service equipment.
●
Connect all cables only to the specified connection points.
●
Do not install any external modems in the installation cabinets.
●
Do not allow readily flammable materials to be stored near the installation or in the
installation room.
●
Ensure good lighting at the workplace.
●
Untidiness at the workplace involves the risk of injuries.