Call management (CM
)
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
6-13
Initial operation
Figure 6-6 Call Management (example, continued)
Block 3
15191
= Call dest. lists
Block 4
15 = Incoming calls
1519
= Call forwarding
15 = Incoming calls
15196
= Group setup
Call dest.
list 1
list 2
list 3
881
(group 1)
882
(group 2)
* = Ext. number
dialled
Call dest.
list 14
list 15
list 16
888
(group 8)
Call Management dests.
15197
=
Common ringer, mode
1 = Called immediately
2 = Called after the first forwarding timeout (column 5)
.
.
.
.
Entries:
– = No entry
11–74 = The port assigned to the
number is called
881–888 = Group 1–8 with the
defined call type
*
= Selected ext. no. of station
# = System search operation (as of SW 2.1= #9)
870–873 = Pseudo ports (870=fax; 871=DDI; 872=fax/DDI; 873=announcement before notification)
.
.
.
.
Call first forwarded
to ext. 14
15161
= Ext. called
8 extensions per address
Entries –, 11-74
15162
= Call type
1 = Cyclic hunting group
2 = Linear hunting group
3 = Group ringing
15196
=
Common ringer, PEN
– = No common ringer
11–74 = The port assigned to the number is called
*1–*4 = Relay option, actuator 1–4
15195
=
Number of ring attempts
No. of ring attempts before call is forwarded(1–15)
. . . . .
1
3
.
.
.
.
.
.
1
23
4
567
8
––
––
14 28 72 19
3712
23
11
3712
1
1
2
1
*
*
1. 2. 3.
4.
5.
.
.
.
.
.
.
.
.
.
881
11
14
20
*
*
881
882
888
883
883
14
14
28
1
11
74
2
1
1
1
1
3
3
3
5
3
3
3–
*1
––
881
10
21