Station attributes
Programming guide
A31003-K16-X001-3-7620
,
07/99
10-28
Hicom 100 E Version 2.1, Service manual
10.5.3.3 Controlling the door opener via a door opener adapter (as of SW version
2.0.2)
An existing power source can be connected to an electromagnetic door opener via a floating
contact on a door opener adapter. A door opener can be set up for each door (1 to 4). "DTMF"
must be released for the door opener in question if it is also to be operated by entering a code
at the entrance telephone.
Example
: a door opener with DTMF is set up for door 2.
10.5.3.4 Diverting calls to receiving extension for the doorbell (as of SW version
2.0.2)
Even if an external diversion destination has been programmed for the receiving extension of
a doorbell, incoming calls at this extension are not automatically diverted to the external
destination. Diversion of calls from the entrance telephone to an external destination can be
released for each door (1–4).
Example
: calls from door 2 should also be diverted to external destinations set for the receiving
extension for the doorbell.
Input sequence Meaning Display
A2 3 3
Door opener for door 1
(select door 1 to 4 with "+" and "–" or
directly with "#")
Door 1: not available
B+
Scroll to door 2 Door 2: not available
C
* Change input Door 2:
D2
Door opener feature with DTMF ON Door 2: with DTMF
E<OK>
Confirm input Door 2: with DTMF
F
<F8> Return to Start menu System administration
A door opener feature without DTMF can be activated by entering "1" under point D. An
activated door opener feature can be deactivated by entering "0" under point D.
Input sequence Meaning Display
A2 3 4
Doorbell diversion for door 1
(select door 1 to 4 with "+" and "–" or
directly with "#")
Door 1: do not activate
B+
Scroll to door 2 Door 2: do not activate
C
* Change input Door 2:
D1
Doorbell diversion ON Door 2: activate
E<OK>
Confirm input Door 2: activate
F
<F8> Return to Start menu System administration
Doorbell diversion can be blocked again by entering "0" under point D.