Station attributes
Programming guide
A31003-K16-X001-3-7620
,
07/99
10-32
Hicom 100 E Version 2.1, Service manual
10.5.4.5 Barred numbers list up to SW version 2.0.1+
The numbers entered in this list cannot be dialled by extensions with class-of-service level <3>.
No other numbers are subject to restriction.
25 items are available for barred numbers.
Example
: the extensions with class-of-service level <3> are to be authorised to telephone
within Germany only (no "00" prefix) but they may not access any 0190 numbers.
10.5.4.6 Barred numbers list as of SW version 2.0.2
As of SW 2.0.2, a barred numbers list (Iist 1) with 45 items plus 5 additional barred numbers
lists (2 to 6), each with 10 items, are available.
The class-of-service level <8> corresponds to barred numbers list 1, while the class-of-service
level <9> corresponds to barred numbers list 2 ... and so on.
Input sequence Meaning Display
A1 4 4
Barred numbers item 1
(select item 1 to 25 with "+" and "–" or
directly with "#")
Item 1: –
B+
Change input Item 1:
C00
First barred number = 00 Item 1: 00
D<OK>
Confirm input Item 1: 00
E+
Scroll to item 2 Item 2: –
F
* Change input Item 2:
G
0190 Second barred number = 0190 Item 2: 0190
H
<OK> Confirm input Item 2: 0190
J
<F8> Return to Start menu System administration
A barred number can be deleted from the list by pressing the F3 key under point C or G.