System settings
Programming guide
A31003-K16-X001-3-7620
,
07/99
10-74
Hicom 100 E Version 2.1, Service manual
10.7.15.4 Recording the call duration
If incoming calls are output in the data record, the call duration before the call is answered is
also output. Output of the call duration can be deactivated if required.
Example
: the call duration is not to be output.
10.7.15.5 Output on ringing
If incoming calls are output in the data record, each call received is logged in the data record
as an additional information line. Output can be deactivated if you do not want this information
line to be logged.
Example
: the information line for incoming calls is not to be logged (SW 2.0.2 only).
10.7.15.6 Changing the charge factor
The charge factor is set to "5" by default (to "12" as of SW version 2.0.1+).
It can be changed to any value up to 65535.
Input sequence Meaning Display
A 1 1 3 4
Call duration output Output: yes
B
* Change input Output:
C0
No call duration output Output: no
D<OK>
Confirm input Output: no
E
<F8> Return to Start menu System administration
The call duration output can be activated by entering "1" under point C.
Input sequence Meaning Display
A 1 1 3 5 (up to SW2.0.2)
11 7 (as of SW2.1)
on ringing Output: yes
B
* Change input Output:
C0
Do not output information line Output: no
D<OK>
Confirm input Output: no
E
<F8> Return to Start menu System administration
Output of the information line is activated by entering "1" under point C.