Program instructions
7.5 Convert
S7-200 SMART
System Manual, 09/2015, A5E03822230-AC
201
Examples: I_DI, DI_R, and BCD_I
LAD STL
Convert inches to centimeters:
1. Load a counter value (inches) into
AC1 (ex. C10=101).
2. Convert the value to a real number
(ex. VD0=101.0).
3. Multiply by 2.54 to convert to centi-
meters
(ex. VD4=2.54, VD8=256.54).
4. Convert the value back to an integer
(ex. VD12=257).
Network 1
LD I0.0
ITD C10, AC1
DTR AC1, VD0
MOVR VD0, VD8
*R VD4, VD8
ROUND VD8, VD12
Convert a BCD value to an integer (ex.
AC0=1234, execute BCD_I, then
AC0=04D2).
Network 2
LD I0.3
BCDI AC0
See also
Assigning a constant value for instructions
See also
Assigning a constant value for instructions (Page 69)

Table of Contents

Other manuals for Siemens Simatic S7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic S7 Series and is the answer not in the manual?

Siemens Simatic S7 Series Specifications

General IconGeneral
CPUVaries by model (e.g., S7-300, S7-400, S7-1200, S7-1500)
Communication InterfacesPROFIBUS, PROFINET, Ethernet, MPI
ProgrammingTIA Portal, STEP 7
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
I/O ModulesDigital, Analog, Specialty modules available
Operating Temperature0°C to 60°C (standard models)
MountingDIN rail mounting
Operating Voltage24V DC or 120/230V AC (varies by model)
Protection ClassIP20 (standard models)
MemoryVaries depending on the S7 model. Includes work memory (RAM) for program execution, load memory (EEPROM or Flash) for program storage, and system memory for operating system functions. Memory sizes range from kilobytes to megabytes.

Related product manuals