DETERGENT INJECTION
Overview
2-9317-600-00-0 Aquastorm™ Series Options Guide 9-171
Procedure Configure for saponifier operation as follows:
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key twice to display configuration screen #3.
3. Press the enter key to toggle to YES and indicate the saponifier (detergent
injection unit) is installed.
4. Press the enter key to accept the configuration.
5. Press the Menu key to accept the changes.
6. he update screen displays and the system returns to the main menu.
Diagrams Figure 9–3 displays Configuration Screen #4. Figure 9–4 shows the alarm
process screen.
Figure 9–3
Figure 9–4
ALARM_PROCESS SET
WATCH_DOG TEST
PRE_WASH_FLOW YES
FINAL_RINSE_FLOW YES
FLOW_UNITS GPM
GAS_HEAT_WASH NO
GAS_HEAT_RINSE NO
MACH_LEN_PCT 50
ALARM BAND ACTION REALARM
CONV 1.0 FPM WARNING 05 MIN
WASH 10 F SHUTDOWN 05 MIN
CHEM 10 F IGNORE 05 MIN
RINSE 10 F SHUTDOWN 05 MIN
BLWR 10F WARNING 05 MIN
SAPON SHUTDOWN 05 MIN
BLWR_FAIL SHUTDOWN 05 MIN