DETERGENT INJECTION
Overview
9-172 Aquastorm™ Series Options Guide Rev. 1
9
Procedure Configure the saponifier low level alarm as follows:
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key three (3) times to display configuration screen #4.
3. Press the enter key to access the alarm process screen.
4. Press the arrow keys to highlight the saponifier line.
5. Press the enter key to toggle to Shutdown as the alarm action when the
saponifier level reaches the low level sensor.
6. Use the number keys to set the time, in minutes, to pass before the alarm
reactivates.
7. After configuring the alarm, press the menu key once to save the changes.
8. The update screen displays and the system returns to the main menu.
9. Begin system operation. For detailed information refer to the Aquastorm 200™
Programming and Operations Guide.
Reference When using alarms keep the following information in mind:
In general, alarms are disabled during periods of start up or after a set point
change to prevent nuisance alarms during machine stabilization.
When a status light tower is installed, it displays green to indicate the
machine is at operating level and all alarms will function at their predeter-
mined level.
For tanks, alarms are disabled for up to 30 minutes. When the temperature
reaches within 2 °F of the set point temperature, alarm delay reduces to two
(2) minutes.
For optional IR heaters, alarms are disabled for up to 15 minutes. When the
temperature reaches within 5 °F of the set point temperature, alarm delay
reduces to five (5) minutes.
The resistivity alarm is disabled for five (5) minutes after the final rinse is
turned On.