SAFETY INFORMATION
Attach Machine Lock-Out Tag-Out Device
2-9317-600-00-0 Aquastorm™ Series Options Guide -13
Figure 1–5
Procedure 1. Ensure there are no boards or other product in the system.
2. Notify all affected employees.
3. Locate and identify the types of energy sources used, potential hazards, and
all control devices.
4. Turn Off all operating controls.
5. Locate the facility main power input to the system.
6. Turn the facility main power input device to the Off or Stop position.
7. Secure the facility main power lock-out device in place.
8. Test operating controls. Put all controls in the On position. Be sure no one can
get hurt before testing.
9. Return all operating controls to the Off position before proceeding.
Aquastorm 100
ELECTROVERT