EasyManua.ls Logo

YASKAWA Sigma-7 SGD7S Series - Page 137

YASKAWA Sigma-7 SGD7S Series
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 95: Write Prohibition Setting - OK Button - SigmaWin+
6. To enable the new setting, turn the power supply to the SERVOPACK OFF and ON
again.
This concludes the procedure to prohibit or permit writing parameter settings.
If you prohibit writing parameter settings, you will no longer be able to execute some
functions. Refer to the following table.
SigmaWin+ Digital Operator When
Writing Is
Prohibited
Reference
Menu
Dialog Box
Button
SigmaWin+
Function
Name
Fn No. Utility Func-
tion Name
Setup Origin
Search
*1
Fn003 Origin
Search
Cannot be
executed.
Ä
Chap.
8.7.3 ‘Origin
Search’
page 284
Absolute
Encoder
Reset
Fn008 Reset Abso-
lute Encoder
Cannot be
executed.
Ä
Chap.
6.16.5 ‘Oper-
ating Proce-
dure’
page 188
Adjusting the
Analog Mon-
itor Output
Fn00C Adjust
Analog Mon-
itor Output
Offset
Cannot be
executed.
Ä
Chap.
10.4.4 ‘Using
the Analog
Monitors’
page 441
Fn00D Adjust
Analog Mon-
itor Output
Gain
Cannot be
executed.
Motor Cur-
rent Detec-
tion Offset
Adjustment
Fn00E Autotune
Motor Cur-
rent Detec-
tion Signal
Offset
Cannot be
executed.
Ä
Chap.
7.13.2 ‘Auto-
matic Adjust-
ment’
page 252
Restrictions
Sigma-7 Series SERVOPACKs
Basic Functions That Require Setting before Operation
Manipulating SERVOPACK Parameters (Pn) > Write Prohibition Setting for SERVOPACK Parameters