Tool Function Reference
Digital Operator Fn010
& Σ-7-Series Digital Oper-
ator Operating Manual
(Manual No.: SIEP
S800001 33)
SigmaWin+ Setup - Write Prohibited
Setting
Ä
‘Operating Procedure’
page 136
Use the following procedure to prohibit or permit writing parameters.
1.
Click the Servo Drive Button in the workspace of the Main Window of the Sig-
maWin+.
2. Select Write Prohibition Setting in the Menu Dialog Box.
The Write Prohibition Setting Dialog Box will be displayed.
3.
Press the
or for the rightmost digit and set one of the following.
0000: Writing is permitted (default setting).
0001: Writing is prohibited.
Fig. 93: Writing is permitted SigmaWin+
4. Click the Setting Button.
Fig. 94: Writing is prohibited SigmaWin+
5. Click the OK Button.
The setting will be written to the SERVOPACK.
Operating Procedure
Sigma-7 Series SERVOPACKs
Basic Functions That Require Setting before Operation
Manipulating SERVOPACK Parameters (Pn) > Write Prohibition Setting for SERVOPACK Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 136