Use the following procedure to write the motor parameters to the linear encoder.
1. Prepare the motor parameter file to write to the linear encoder.
2.
Click the Servo Drive Button in the workspace of the Main Window of the Sig-
maWin+.
3. Select Motor Parameter Scale Write in the Menu Dialog Box.
ð
The Motor Parameter Scale Write Dialog Box will be displayed.
4. Click the OK Button.
Fig. 100: Motor parameter scale write - Warning
ð
Click the Cancel Button to cancel writing the motor parameters to the linear
encoder. The Main Window will return.
If the write is completed normally, the Motor Parameter Scale Write - File Select
Dialog Box will be displayed.
5. Click the Ref. Button.
Fig. 101: Motor parameter scale write - File select