Third Stage Notch Filter Frequency
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn417 50 to 5,000 1 Hz 5,000 Immediately Tuning
(applies to Speed Control, Position Control and Torque Control)
Third Stage Notch Filter Q Value
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn418 50 to 1,000 0.01 70 Immediately Tuning
(applies to Speed Control, Position Control and Torque Control)
Third Stage Notch Filter Depth
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn419 0 to 1,000 0.001 0 Immediately Tuning
(applies to Speed Control, Position Control and Torque Control)
Fourth Stage Notch Filter Frequency
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn41A 50 to 5,000 1 Hz 5,000 Immediately Tuning
(applies to Speed Control, Position Control and Torque Control)
Fourth Stage Notch Filter Q Value
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn41B 50 to 1,000 0.01 70 Immediately Tuning
(applies to Speed Control, Position Control and Torque Control)
Fourth Stage Notch Filter Depth
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn41C 0 to 1,000 0.001 0 Immediately Tuning
(applies to Speed Control, Position Control and Torque Control)
Sigma-7 Series SERVOPACKs
Tuning
Manual Tuning > Tuning the Servo Gains
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 413