This read only parameter contains the Name of Station for the PROFINET IO Network
Interface, which is related to this Drive Unit. This is an additional service parallel to the
standard PROFINET IO mechanism, which makes the Name of Station also accessible
via PROFIdrive Parameter Access.
PNU
(dec)
Name Data Type Access PDO Map-
ping
Value Saving to
EEPROM
61000 Name of Station OS[240] RO No - Yes
This read only parameter contains the IP Address of the Station for the PROFINET IO
Network Interface, which is related to this Drive Unit. This is an additional service parallel
to the standard PROFINET IO mechanism, which makes the IP Address of Station also
accessible via PROFIdrive Parameter Access.
PNU
(dec)
Name Data Type Access PDO Map-
ping
Value Saving to
EEPROM
61001 Ip of Station OS[4] RO No - Yes
This read only parameter contains the MAC Address of the Station for the PROFINET IO
Network Interface, which is related to this Drive Unit. This is an additional service parallel
to the standard PROFINET IO mechanism, which makes the MAC Address of Station
also accessible via PROFIdrive Parameter Access.
PNU
(dec)
Name Data Type Access PDO Map-
ping
Value Saving to
EEPROM
61002 Mac of Station OS[6] RO No - Yes
This read only parameter contains the Next Default Gateway for the Station for the
PROFINET IO Network Interface, which is related to this Drive Unit. This is an additional
service parallel to the standard PROFINET IO mechanism, which makes the Next Default
Gateway of the Station also accessible via PROFIdrive Parameter Access.
PNU
(dec)
Name Data Type Access PDO Map-
ping
Value Saving to
EEPROM
61003 Standard Gateway of Sta-
tion
OS[4] RO No - Yes
This read only parameter contains the Subnet Mask of the Station for the PROFINET IO
Network Interface, which is related to this Drive Unit. This is an additional service parallel
to the standard PROFINET IO mechanism, which makes the Subnet Mask of the
PROFINET interface also accessible via PROFIdrive Parameter Access.
PNU
(dec)
Name Data Type Access PDO Map-
ping
Value Saving to
EEPROM
61004 Subnet Mask of Station OS[4] RO No - Yes
Name of Station
Ip of Station
Mac of Station
Standard Gateway of Sta-
tion
Subnet Mask of Station
Sigma-7 Series SERVOPACKs
Object Dictionary
General Objects
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 532

Table of Contents