n.X
Function Selection for Undervoltage Reference
0 Do not detect undervoltage.
Ä
Chap. 7.4
‘SEMI F47
Function’
page 209
1 Detect undervoltage warning and limit torque at
host controller.
2 Detect undervoltage warning and limit torque with
Pn424 and Pn425 (i.e., only in the SERVOPACK).
n.X
Warning Detection Selection Reference
0 Detect warnings.
Ä
Chap. 16.5
‘Warning Dis-
plays’ page 637
1 Do not detect warnings except for A.971.
n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn009 2 Application
Function
Selections 9
0000h to
0121h
0010h All After
restart
Tuning -
n.X
Reserved parameter (Do not change.)
n.X
Current Control Mode Selection Reference
0 Use current control mode 1.
Ä
Chap. 9.13.5
‘Current Control
Mode Selection’
page 398
1
n SERVOPACK Models SGD7S-R70A, -R90A,
-1R6A, -2R8A, -3R8A, -5R5A, and -7R6A: Use
current control mode 1.
n SERVOPACK Models SGD7S-120A, -180A,
-200A, -330A, -470A, -550A, -590A, and
-780A: Use current control mode 2.
2 Use current control mode 2.
n.X
Speed Detection Method Selection Reference
0 Use speed detection 1.
Ä
Chap. 9.13.7
‘Speed Detec-
tion Method
Selection’
page 399
1 Use speed detection 2.
n.X
Reserved parameter (Do not change.)
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 667