n.X
Function Selection for Test without a Motor Applicable
Motors
0 Disable tests without a motor. All
1 Enable tests without a motor.
n.X
Encoder Resolution for Tests without a Motor Applicable
Motors
0 Use 13 bits. Rotary
1 Use 20 bits.
2 Use 22 bits.
3 Use 24 bits.
n.X
Encoder Type Selection for Tests without a Motor Applicable
Motors
0 Use an incremental encoder. All
1 Use an absolute encoder.
n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn00D 2 Application
Function
Selections D
0000h to
1001h
0000h All After
restart
Setup
Ä
Chap.
6.11.5
‘Over-
travel
Warnings’
page 163
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Overtravel Warning Detection Selection
0 Do not detect overtravel warnings.
1 Detect overtravel warnings.
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters