Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn00F 2 Application
Function
Selections F
0000h to
2011h
– 0000h All After
restart
Setup –
n.X
Preventative Maintenance Warning Selection Reference
0 Do not detect preventative maintenance warnings.
Ä
Chap. 10.5.3
‘Preventative
Maintenance’
page 451
1 Detect preventative maintenance warnings.
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn021 2 Reserved
parameter
(Do not
change.)
– – 0000h All – – –
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn022 2 Application
Function
Selections 22
0000h to
0011h
– 0000h All After
restart
Setup –
n.X
Overtravel Release Method Selection Reference
0 Overtravel exists while the P-OT or N-OT signal is
being input.
Ä
Chap. 6.11.6
‘Overtravel
Release
Method Selec-
tion’ page 165
1 Overtravel exists while the P-OT or N-OT signal is
input and the current position of the workpiece is
separated from the P-OT signal or N-OT signal.
n.X
Reserved parameter (Do not change.)
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters