EasyManua.ls Logo

YASKAWA Sigma-7 SGD7S Series - Page 673

YASKAWA Sigma-7 SGD7S Series
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn081 2 Application
Function
Selections 81
0000h to
1111h
0000h All After
restart
Setup
Ä
Chap.
7.6
‘Encoder
Divided
Pulse
Output’
page 213
n.X
Phase-C Pulse Output Selection
0 Output phase-C pulses only in the forward direction.
1 Output phase-C pulses in both the forward and reverse directions.
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn100 2 Speed Loop
Gain
10 to
20,000
0.1 Hz 400 All Immedi-
ately
Tuning
Ä
Chap.
9.14
‘Manual
Tuning’
page 405
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn101 2 Speed Loop
Integral Time
Constant
15 to
51,200
0.01 ms 2000 All Immedi-
ately
Tuning
Ä
Chap.
9.14
‘Manual
Tuning’
page 405