Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn212 4 Number of
Encoder
Output
Pulses
16 to
1,073,741
,824
1 P/Rev 2048 Rotary After
restart
Setup
Ä
Chap.
7.6.3 ‘Set-
ting for
the
Encoder
Divided
Pulse
Output’
page 218
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn22A 2 Fully-closed
Control
Selections
0000h to
1003h
– 0000h Rotary After
restart
Setup
Ä
Chap.
11.4.10
‘Setting to
Use an
External
Encoder
for Speed
Feedback’
page 463
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Fully-closed Control Speed Feedback Selection
0 Use motor encoder speed.
1 Use external encoder speed.
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn230 2 Position Con-
trol Expan-
sion Function
Selections
0000h to
0001h
– 0000h All After
restart
Setup
Ä
Chap.
9.13.9
‘Backlash
Compen-
sation’
page 400
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters