Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn282 2 Linear
Encoder
Scale Pitch
0 to
6,553,600
0.01 μm 0 Linear After
restart
Setup
Ä
Chap.
6.6 ‘Set-
ting the
Linear
Encoder
Pitch’
page 146
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn304 2 Jogging
Speed
0 to
10,000
1 min
-1
500 Rotary Immedi-
ately
Setup
Ä
Chap.
8.4.2
‘Prepara-
tions’
page 268
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn305 2 Soft Start
Acceleration
Time
0 to
10,000
1 ms 0 All Immedi-
ately
Setup
*1
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn306 2 Soft Start
Deceleration
Time
0 to
10,000
1 ms 0 All Immedi-
ately
Setup
*1
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn308 2 Speed Feed-
back Filter
Time Con-
stant
0 to
65,535
0.01 ms 0 All Immedi-
ately
Setup
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Sigma-7 Series SERVOPACKs