Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn30A 2 Deceleration
Time for
Servo OFF
and Forced
Stops
0 to
10,000
1 ms 0 All Immedi-
ately
Setup
Ä
Chap.
6.11.4
‘Motor
Stopping
Method
for Over-
travel’
page 162
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn30C 2 Speed Feed-
forward
Average
Movement
Time
0 to 5,100 0.1 ms 0 All Immedi-
ately
Setup
Ä
Chap.
9.14.3
‘Compat-
ible
Adjust-
ment
Functions’
page 419
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn310 2 Vibration
Detection
Selections
0000h to
0002h
0000h All Immedi-
ately
Setup
Ä
Chap.
7.12 ‘Initi-
alizing the
Vibration
Detection
Level’
page 246
n.X
Vibration Detection Selection
0 Do not detect vibration.
1 Output a warning (A.911) if vibration is detected.
2 Output an alarm (A.520) if vibration is detected.
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)