Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn311 2 Vibration
Detection
Sensitivity
50 to 500 1% 100 All Immedi-
ately
Tuning
Ä
Chap.
7.12 ‘Initi-
alizing the
Vibration
Detection
Level’
page 246
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn312 2 Vibration
Detection
Level
0 to 5,000
1 min
-1
50 Rotary Immedi-
ately
Tuning
Ä
Chap.
7.12 ‘Initi-
alizing the
Vibration
Detection
Level’
page 246
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn316 2 Maximum
Motor Speed
0 to
65,535
1 min
-1
10000 Rotary After
restart
Setup
Ä
Chap.
7.5 ‘Set-
ting the
Motor
Maximum
Speed’
page 212
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn324 2 Moment of
Inertia Calcu-
lation Starting
Level
0 to
20,000
1% 300 All Immedi-
ately
Setup
Ä
Chap.
9.7.6
‘Trouble-
shooting
Problems
in Auto-
tuning
without a
Host Ref-
erence’
page 333