Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn383 2 Jogging
Speed
0 to
10,000
1 mm/s 50 Linear Immedi-
ately
Setup
Ä
Chap.
8.4 ‘Trial
Operation
for the
Servo-
motor
without a
Load’
page 267
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn384 2 Vibration
Detection
Level
0 to 5,000 1 mm/s 10 Linear Immedi-
ately
Tuning
Ä
Chap.
7.12 ‘Initi-
alizing the
Vibration
Detection
Level’
page 246
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn385 2 Maximum
Motor Speed
1 to 100 100 mm/s 50 Linear After
restart
Setup
Ä
Chap.
7.5 ‘Set-
ting the
Motor
Maximum
Speed’
page 212
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn401 2 First Stage
First Torque
Reference
Filter Time
Constant
0 to
65,535
0.01 ms 100 All Immedi-
ately
Tuning
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters