Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn587 2 Polarity
Detection
Execution
Selection for
Absolute
Linear
Encoder
0000h to
0001h
– 0000h Linear Immedi-
ately
Setup –
n.X
Polarity Detection Selection for Absolute Linear
Encoder
Reference
0 Do not detect polarity.
Ä
Chap. 6.10
‘Polarity Detec-
tion’ page 157
1 Detect polarity.
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn600
*6
2 Regenerative
Resistor
Capacity
*2
Depends
on
model.
*3
10 W 0 All Immedi-
ately
Setup
Ä
Chap.
6.18 ‘Set-
ting the
Regener-
ative
Resistor
Capacity’
page 194
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn601 2 Dynamic
Brake
Resistor
Allowable
Energy Con-
sumption
0 to
65,535
10 J 0 All After
restart
Setup
*6
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters