Page #153 background image
Symbologies
153
ISBT Concatenation Redundancy
Parameter # 223
SSI # DFh
If you set ISBT Concatenation to Autodiscriminate, use this parameter to set the number of times the scanner
must decode an ISBT symbol before determining that there is no additional symbol.
Scan the following barcode, and then scan barcodes in Numeric Barcodes to set a value between 2 and 20. Enter
a leading zero for single digit numbers. To correct an error or change a selection, scan Cancel on page 426. The
default is 10.
Code 128 <FNC4>
Parameter # 1254
SSI # F8h 04h E6h
This feature applies to Code 128 barcodes with an embedded <FNC4> character. Select Ignore Code 128
<FNC4> to strip the <FNC4> character from the decode data. The remaining characters are sent to the host
unchanged. When disabled, the <FNC4> character is processed normally as per Code 128 standard.
ISBT Concatenation Redundancy
*Honor Code 128 <FNC4>
(0)
Ignore Code 128 <FNC4>
(1)

Table of Contents

Other manuals for Zebra DS9908

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS9908 and is the answer not in the manual?

Zebra DS9908 Specifications

General IconGeneral
SealingIP52
Scan TechnologyArray Imager
Scan RateUp to 240 in./610 cm per second
Humidity5% to 95% RH, non-condensing
Decode Capability1D, 2D
ConnectivityUSB, RS-232, Keyboard Wedge
Image Sensor1280 x 800
Drop SpecificationMultiple 5 ft./1.5 m drops to concrete
Operating Temperature14°F to 122°F (-10°C to 50°C)
Light SourceLED
Storage Temperature-40°F to 158°F (-40°C to 70°C)