305
OCR Programming
Introduction
This chapter describes how to set up the scanner for OCR programming. The scanner can read 6 to 60 point OCR
typeface. It supports font types OCR-A, OCR-B, MICR E13B, and US Currency Serial Number.
OCR is not as secure as a barcode. To decrease OCR misdecodes and speed OCR reading, set an accurate OCR
template and character subset, and use a check digit.
All OCR fonts are disabled by default. Enabling OCR could slow barcode decoding. You can enable OCR-A and
OCR-B at the same time, but not other combined font types.
Setting Parameters
To set feature values, scan a single barcode or a short barcode sequence. The settings are stored in non-volatile
memory and are preserved even when the imager powers down.
To return all features to default values, scan the Set Factory Defaults on page 59. Throughout the programming
barcode menus, asterisks (
*) indicate default values.
NOTE: Most computer monitors allow scanning barcodes directly on the screen. When scanning from the screen,
be sure to set the document magnification to a level where you can see the barcode clearly, and bars and/or
spaces do not merge.
*Enable Parameter
(1)
Feature/option
* Indicates default
Option value