Maintenance, Troubleshooting, and Technical Specifications
50
Scanner emits
low/high/low/high beeps
during programming.
Out of host parameter storage
space.
Scan Default Parameters on page 59.
Out of memory for ADF rules. Reduce the number of ADF rules or the
number of steps in the ADF rules.
During programming, indicates
out of ADF parameter storage
space.
Erase all rules and re-program with shorter
rules.
Scanner emits low/high/low
beeps.
ADF transmit error. Refer to the Advanced Data Formatting
Guide for information.
Invalid ADF rule is detected. Refer to the Advanced Data Formatting
Guide for information.
Scanner emits a power-up
beep after changing USB
host type.
The USB bus re-established
power to the scanner.
Normal when changing USB host type.
Scanner emits one high
beep when not in use.
In RS-232 mode, a <BEL>
character was received and Beep
on <BEL> option is enabled.
Normal when Beep on <BEL> is enabled
and the scanner is in RS-232 mode.
Scanner emits frequent
beeps.
No power to the scanner. Check the system power. If the configuration
requires a power supply, re-connect the
power supply.
Incorrect host interface cable is
used.
Verify that the correct host interface cable is
used. If not, connect the correct host
interface cable.
Interface/power cables are loose. Check for loose cable connections and
re-connect cables.
Scanner emits five long low
beeps after a barcode is
decoded.
Conversion or format error was
detected.
The scanner conversion
parameters are not properly
configured.
Ensure the scanner conversion parameters
are properly configured.
Conversion or format error was
detected.
An ADF rule was set up with
characters that can't be sent for
the host selected.
Change the ADF rule, or change to a host
that can support the ADF rule.
Conversion or format error was
detected.
A barcode was scanned with
characters that can't be sent for
that host.
Change the barcode, or change to a host that
can support the barcode.
Table 5 Troubleshooting (Continued)
Problem Possible Causes Possible Solutions