CAPINTEC, INC. CAPTUS
®
4000e
August 15 MCA 13-1
CHAPTER 13
MCA
INTRODUCTION ............................................................................................ 13-1
ACQUISITION AND COUNT DATA ............................................................... 13-2
Channel Data Display ................................................................................ 13-2
CHANGING DETECTORS ............................................................................. 13-3
SPECTRUM SCALE & ZOOMING ................................................................. 13-3
Vertical Zoom ............................................................................................ 13-3
Horizontal Zoom ........................................................................................ 13-4
COUNTING SETUP ........................................................................................ 13-7
SPECTRUM ID (NAME) ................................................................................. 13-7
REGIONS OF INTEREST (ROI) ..................................................................... 13-8
SAVE AND RESTORE COUNT DATA OR MCA SETTINGS ........................ 13-10
Save Spectrum ......................................................................................... 13-10
Recall Spectrum ....................................................................................... 13-11
Export to Excel ......................................................................................... 13-12
Export Raw Spectrum .............................................................................. 13-13
Save MCA Settings ................................................................................... 13-13
Recall MCA Settings................................................................................. 13-13
Save Counting Setup ............................................................................... 13-13
Recall Counting Setup ............................................................................. 13-14
Restore Current Settings ......................................................................... 13-14
PRINTING MCA DATA .................................................................................. 13-14
CUSTOMIZING MCA SETTINGS .................................................................. 13-14
High Voltage ............................................................................................. 13-15
Gain ........................................................................................................... 13-15
Zero Offset ................................................................................................ 13-16
Threshold .................................................................................................. 13-16
MANUAL CALIBRATION .............................................................................. 13-17
INTRODUCTION
The CAPTUS
®
4000e includes a fully functional multichannel analyzer (MCA) board. The
MCA Module provides custom control of the MCA parameters and data acquisition for
special applications:
All MCA parameters are software controlled.
Up to 16 Regions of Interest (ROI) can be defined at one time.
Counting can be performed using live time, real time or peak counts.
Spectral data and MCA settings can be saved to hard disk.
Count data and the spectrum can be printed.