1‑161
Chapter 1 Troubleshooting
Version 2 2007.05.22
FIP-1. 59 CRUM ID 009-371/Insert Belt Unit 094-910
Does the error still
occur when the
power is turned ON?
NoYes
Possible causative parts:BELT CRU (PL4.1.1)
PWBA MCU (PL9.1.20)
Checking after replacing
the BELT CRU.
Replace the BELT CRU.
Does the error still
occur when the
power is turned ON?
NoYes
Replace the PWBA
MCU. (Removal 67/
Replacement 55)
Checking BELT CRU installation.
Reseat the BELT CRU.
END
END
Checking the BELT CRU
model.
Is the BELT CRU
installed the 3115cn?
NoYes
Replace the BELT
CRU.

Table of Contents