Chapter 1 Troubleshooting
Version 2 2007.05.22
FIP-1. 64 Tray Detached 024-946/024-947 / Load Tray 1 077-912/
Illegal Settings (Copy Select Tray Boken)/Illegal Settings
(Copy Select Tray Remove)/Illegal Settings (Copy Select Tray Exit)
Does the error still
occur when turning
on the power?
NoYes
Possible causative parts:CASSETTE ASSY 250 (PL2.1.1)
SWITCH ASSY SIZE (PL7.1.18)
PWBA MCU (PL9.1.20)
550 OPTION FEEDER (PL13.7.1)
CASSETTE ASSY 550 (PL12.4.1)
Checking the CASSETTE ASSY
installation
Reseat the CASSETTE ASSY.
END
NoYes
Checking the Switch
Assy Size
Does the Switch Assy
Size function normally?
Checked by [Digital Input]
- [DI-18] in [IOT
Diagnosis].
END
Checking after replacing
the CASSETTE ASSY 250
Replace the CASSETTE
ASSY 250.
Does the error still
occur when turning
on the power?
NoYes
END
Tray2
Tray1
Checking after replacing
the SWITCH ASSY SIZE
Replace the SWITCH
ASSY SIZE. (Removal 19/
Replacement 27)
Does the error still
occur when turning
on the power?
NoYes
END
Replace the PWBA
MCU. (Removal 67/
Replacement 55)
A